The above application table based on GB16899-2011.
* Moving walk has other than the above specificatons, such as those with a speed of 40m/min or an inclination not exceeding 12° degress, can also be supplied. For further details as well as the specifications other than the standard ones, please contact Toshiba.
Item | Interior panel | Optional Specification |
---|---|---|
Application | TC series moving walk | |
Control type | Single speed | Automatic operation with low speed and stop by stand-by mode (without poles type.) is optional specifications. |
Temperature | 0℃ or more, 40℃ or less | |
Humidity | Monthly av. 90% or less Daily mean 95% or less, No dew drop |
|
Power supply | For main power: Three phase AC. 380V-50Hz | Three phase AC. 380V-60Hz,AC.400V-50Hz, AC.415V-50Hz, AC.440V-50Hz |
For lighting: Single phase AC.220V-50Hz * Note 1 |
Single phase AC. 220V-60Hz,AC.230V-50Hz, AC.240V-50Hz | |
Voltage tolerance for main power | ±10% or less in machine room terminal. | |
Voltage unbalance factor | 5% or less | |
Frequency tolerance | ±5% | |
Voltage tolerance for lighting | ±5% or less in machine room terminal. | |
Installation place | Sheltered indoor spot | Outdoor type is not applicable |
Corrosive gas | Don’t exist | * Note 2 |
Explosive gas | Don’t exist | |
Dust | Excessive dust must not exist | 0.3 mg/m3 or less |
Influence salt | Don’t exist | Quantity of sea salt particle NaCl 0.003mg/day/100cm2 or less |
Note 1: When supplying lighting and inspection source from power source, need a step-down transformer.
Note 2: SO3: 0.02mg/day/100cm2 or less, NO2: 0.02mg/100cm2 or less, Cl: 0.006mg/day/100cm2 or less, NH4+: 0.02mg/day/100cm2 or less.
Selected the most suitable color from seven available color variations to match the building use and design concepts.
* Incluted Emergency stop button